Installation method of compressed air filter
①Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.
②The filter element should be replaced regularly. When replacing the filter element, use an Allen wrench to unscrew the four screws of the lower cover and take out the old filter element from below. Carefully record the replacement time. It is recommended that the working time z should not exceed 8000 hours.
③The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;
④Different grades of compressed air filters can be equipped with electronic drain valves or manual valves according to customer requirements.
| PF | AO | AA | AX | ACS | AR | AAR |
| As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
Filtration Grade
PF
AO
AA
AX
ACS
AR
AAR
Size of solid particles(ISO12500-3)
5μm
1μm
0.01μm
0.01μm
-
1μm
0.01μm
Filtration performance of solid particles(ISO12500-3)
-
99.999+%
99.999+%
99.999+%
99.999+%
99.999+%
99.999+%
Filtration performance of oil(ISO12500-1)
50%
80+%
99.9+%
99.99+%
-
-
-
Residual oil content(ISO12500-1)
5mg/m³
0.6mg/m³
<0.01mg/m³
<0.001mg/m³
<0.004mg/m³
-
-
Product Picture

| Model | Pipe size | Flow rates | Dimension (mm) | |||||||
| L/S | m³/min | scfm | W(Width) | D(Depth) | H (Height) | A | B | C(clearance for housing) | ||
| YFB010 | RC1/2" | 16.7 | 1.0 | 35.5 | 96 | 79 | 252 | 29 | 223 | 118 |
| YFB020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 252 | 29 | 223 | 118 |
| YFB030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 286 | 29 | 257 | 153 |
| YFB040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 286 | 29 | 257 | 153 |
| YFB060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 357 | 37 | 320 | 208 |
| YFB070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 458 | 37 | 421 | 303 |
| YFB080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 458 | 37 | 421 | 303 |
| YFB090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 558 | 58 | 500 | 467 |
| YFB100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 558 | 58 | 500 | 467 |
| YFB110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 838 | 58 | 780 | 794 |
| YFB120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 838 | 58 | 780 | 794 |
| YFB130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 645 | 74 | 571 | 514 |
| YFB140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 645 | 74 | 571 | 514 |
| YFB150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 902 | 74 | 828 | 764 |
| YFB160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 902 | 74 | 828 | 764 |
| Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C | |||||||||
| Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
| Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 | |



If you are interested in the product, contact 2bvideo.com for more information for more information
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Main Product:
Compressed Air Dryer,
Compressed Air Filter,
Water Gas Separator,
Condensate Auto Drain,
Air Filter Element ,
Differential Pressure Gauge