Get Quote
730 people are quoting
X

Thermal gas mass flowmeter(1)

2 year ago
11 0
Product details

CXFCTMF thermal gas mass flowmeter
The thermal gas mass flowmeter is designed based on the principle of thermal diffusion.
The meter uses the constant temperature difference method to accurately measure the gas. It has the advantages of small size, high digitization, easy installation and accurate measurement.
The sensor part is composed of two reference level platinum resistance temperature sensors. When the instrument is working, one sensor can continuously measure the medium temperature T1; the other sensor's temperature rises to higher than the medium temperature T2 through self-heating, it is used to sense the flow rate of the fluid,  so it's known as velocity sensor. The temperature △ T =T2-T1, T2>T1, when there is a fluid flowing, gas molecules collide with the sensor and take away the heat of T2, which makes the temperature of T2 reduction. If to keep △ T unchanged, it is necessary to increase the supply current of T2. The faster the gas flows, the more heat will be taken away.
There is a fixed functional relationship between gas flow velocity and the incremental heat, which is the principle of constant temperature difference.


Features and Advantages of the thermal gas mass flow meter: 
1. The real mass flowmeter, to measure the gas flow without temperature and pressure compensation, measurement is convenient and accurate. The mass flow rate or standard volume flow rate of the gas can be obtained.
2. Wide range ratio, can measure the flow rate up to 100Nm/s to 0.5Nm/s gas, can be used for gas leak detection.
3. Good anti-seismic performance and long service life, the sensor has no moving parts and pressure sensing parts, and the measurement accuracy is not affected by vibration.
4. Simple installation and maintenance, and the installation and maintenance can be achieved without stopping production if the site conditions permit (special customization is required).
5. Digital design, overall digital circuit measurement, accurate measurement, easy maintenance.
6. Adopting 4~20mA, RS-485 communication,factory automation, integration will be achieved .

 

Performance Technical Parameter
Measuring Medium Various gases(except acetylene)
Pipe diameter range DN15~DN4000mm
Velocity range 0.1~100Nm/s
Accuracy ± 1~2.5%
Working Temp. Sensor: -40~+220ºC   Converter: -20~+45ºC
Working Pressure Medium Pressure≤1.6MPa(Insertion or full pipe type) or customized
Power Supply DN24V or AC220V ≤18W(Integrated); AC220V ≤19W(Split)
Response rate 1s
Output signal 4~20mA(optoelectronic isolation, Max load 500Ω), Pulse, RS-485(optoelectronic isolation), HART Protocol
Alarm 1~2 relay normally open contact, 10A/220V/AC, 5A/30V/DC
Installation Type Insertion or Conduit
Structure Split or Integrated
Pipe Material CS, SS, Plastic
Display Four lines LCD
Display Content Mass flow rate, Volume flow rate under standard Condition, Accumulative flow rate, standard time, accumulative time, standard flow velocity
Protection Class IP65
Sensor Material SS316
Contact Now

If you are interested in the product, contact 2bvideo.com for more information for more information

To:
Kaifeng Chuangxin Measurement & Control Instrument Co., Ltd.
Message:
Submit
Disclaimer:

The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.

Audited supplier
1 min
Address: Kaifeng, China


Main Product: Flow Meter, Electromagnetic Flowmeter, Turbine Flow Meter , Vortex Flow Meter, Throtolling Devices, Ultrasonic Flow Meter

Disclaimer:
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.