HPL Series Hybrid Solar Charge Inverter 10/12kW

The HPL 10/12kW Hybrid Solar Charge Inverter offers an amazing experience. Its high-efficiency MPPT and pure sine wave output ensure stable power. The sleek design and comprehensive features, like parallel operation and multiple communication ports, make installation and usage convenient. A reliable choice for clean energy solutions.

I. Product Features

  1. High-Efficiency MPPT Technology: The advanced MPPT technology has an efficiency of up to 99.9%, enabling efficient utilization of solar energy.
  2. High-Quality Power Output: It outputs high-quality pure sine wave AC power, ensuring stable and clean power supply for various electrical appliances.
  3. Comprehensive Safety Protection: From hardware to software, it provides comprehensive security measures to protect the system and users.
  4. Aesthetic Industrial Design: With an industrial design that features a modern aesthetic look, it can blend well with different environments.
  5. High Charging Current: The charging current can reach up to 220A, facilitating quick charging of batteries.
  6. Battery Management System: The exclusive Li-ion battery BMS dual activation system ensures the safe and efficient operation of the battery.
  7. Parallel Operation Capability: It allows parallel operation of up to 6 units, increasing the overall power output and flexibility of the system.
  8. High PV Input Current: The PV input current can be up to 22 + 22A, suitable for connecting multiple solar panels.
  9. High Output Power: The maximum output power is 12kW, meeting the power needs of medium to large households or small commercial applications.
 

II. Operating Mode

The inverter can operate in conjunction with solar panels, the utility grid, a generator, and a battery. It can supply power to home loads and communicate via Internet (WiFi-F / GPRS-F), ShinePhone, and ShineServer. This allows for intelligent control and monitoring of the power system.
 

III. Rear Panel

1
  1. AC Output Port: Used to connect the load and supply power.
  2. AC Input Port: Connects to the utility grid or generator.
  3. ON/OFF Rocker Switch: Controls the power on/off of the inverter.
  4. Photovoltaic (PV) Parameters: Displays parameters related to the photovoltaic system.
  5. Battery Parameters: Shows information about the battery, such as voltage and state of charge.
  6. CT Current Sensing for Self-Consumption (Optional): Can be used to monitor self-consumption current (optional).
  7. Dry Contact Port: Can be used for external control or signaling.
  8. RS485 - 2/CAN Communication Port: For communication with other devices.
  9. Parallel Communication Port (Parallel Module Only): Used for parallel connection communication (only for parallel modules).
  10. RS485 - 1 Communication Port: Another communication interface.
  11. USB Communication Port: Enables connection with a computer or other USB devices.
  12. WiFi Port (Optional): For wireless communication (optional).
  13. AC Input Breaker: Protects the AC input circuit.
  14. Grounding Screw Hold: Used for grounding connection.
 

IV. Specification

General

  • Parallel Mode: HPL48100 - 500P and HPL48120 - 500P support parallel operation of 1 - 6 units, while HPL48100 - 500 and HPL48120 - 500 do not support parallel operation.
  • AC Mode: The rated input voltage is 120(L1/N, L2/N)/240Vac(L1/L2). The input phase voltage range is (85Vac - 140Vac)±2%. The frequency is 50Hz/60Hz (auto detection), and the frequency range is 47±0.3Hz - 55±0.3Hz (50Hz) and 57±0.3Hz - 65±0.3Hz (60Hz). Overload/short circuit protection is provided by a circuit breaker. The efficiency is >95%, and the conversion time (bypass and inverter) is 10ms (typical). AC reverse protection is available, and the maximum bypass phase overload current is 2pole, 63A/63A(L1/L2).
 

Inverter Mode

  • Output Voltage Waveform: Pure sine wave.
  • Rated Output Power (VA): For HPL48100 - 500P and HPL48100 - 500, the split-phase rated output power is 10000VA, and the single-phase rated output power is 7600VA (limited by the wiring terminals). For HPL48120 - 500P and HPL48120 - 500, the split-phase rated output power is 12000VA, and the single-phase rated output power is 7600VA (limited by the wiring terminals).
  • Rated Output Power (W): Similar to the VA ratings, with the same limitations for single-phase output. The power factor is 1. The rated output voltage is 120Vac (L1/N, L2/N)/240Vac(L1/L2), and the output voltage error is ±5%. The output frequency range is 50Hz±0.3Hz/60Hz±0.3Hz. The maximum efficiency is >91%. Overload protection is provided with different timeouts depending on the load percentage. The peak power for split-phase is 15000VA for HPL48100 models and 18000VA for HPL48120 models, and the same for single-phase. The loaded motor capability is 5HP for HPL48100 models and 6HP for HPL48120 models. Output short circuit protection can protect after continuous short circuit for 1 second. The bypass circuit breaker phase specification is 2pole, 63A/63A(L1/L2).
 

Battery-related

  • Rated Battery Input Voltage: 51.2V (minimum starting voltage 44V). The battery voltage range is 40.0Vdc - 58.6Vdc±0.6Vdc, and settings such as under-voltage alarm, shutdown voltage, over-voltage alarm, and over-voltage recovery can be configured on the LCD screen.
  • Power Saving Mode Self-Consumption: When the load is ≤25W, the inverter enters power-saving mode.
  • AC Charging: Supports AC charging for lead acid or lithium batteries. The maximum charge current (which can be set) is 120A, and the charge current error is ±5Adc. The charge voltage range is 40 - 58.6Vdc. Short circuit protection is provided by a circuit breaker and blown fuse, and the circuit breaker phase specifications are 2pole, 63A/63A(L1/L2).
  • PV Charging: There are 2 MPPT groups. The maximum PV open circuit voltage is 500Vdc, and the PV operating voltage range is 90Vdc - 500Vdc.
#Online UPS #Offline UPS #Solar Inverter #Line Interactive UPS
Contact Now

If you are interested in the product, contact 2bvideo.com for more information for more information

To:
Shenzhen Honor Power System Co., Ltd
Message:
Submit
Disclaimer:

The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.

Audited supplier
12 month
Address: Shenzhen, China


Main Product: Online UPS, Modular UPS Systems, 3-Phase UPS, Industrial UPS , Line Interactive UPS, Battery And Battery Cabinet

Disclaimer:
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Content Us