The 200QJ32-144/9-22kW cast iron borehole pump provides a matched solution for projects requiring 32 m³/h of clean water at a rated head of 144 m. Its nine-stage pump section and 22 kW submersible motor make it suitable for deep-well extraction, irrigation, tank filling and pressurized water delivery.
This model is suitable for installation in wells with a minimum internal diameter of 200 mm. The slim vertical assembly operates below the water surface, allowing groundwater to be lifted without the suction-depth restrictions associated with above-ground pumps.
Water passes through nine hydraulic stages, with each stage adding pressure before the water enters the next. The resulting 144 m rated head can overcome the pumping water level, site elevation and resistance in the delivery pipeline when the system is correctly designed.
The pump can deliver groundwater to farmland, greenhouses, orchards, livestock facilities, sprinkler lines and drip-irrigation networks. The irrigation system should require a duty point close to 32 m³/h and 144 m after all pipe losses and outlet-pressure demands are included.
This model can pump water from a borehole to an elevated tank, ground-level reservoir, pressure vessel or distribution pipeline. Automatic tank filling can be achieved with level sensors, while pressure-based controls can be used for direct water supply.
The available head makes the pump suitable for installations where groundwater must be lifted and then delivered under pressure. A compatible variable-frequency drive may be used when system demand changes and a more stable outlet pressure is required.
The cast iron structure is suitable for normal clean-water service and provides the strength required for vertical well installation. The pump should not be selected for seawater, aggressive chemicals or strongly corrosive groundwater without first checking material compatibility.
The pumped medium should be clean water without sewage, fibres or large solid particles. Sand should be kept within the permitted level for the selected pump because abrasive particles can wear impellers, guide vanes and bearings.
The well must continuously provide enough water for the required pump output. If the well yield is below 32 m³/h, the dynamic water level may fall rapidly and expose the pump inlet. Well-yield testing is therefore important before installation.
The pump can be integrated with water-level switches, pressure sensors and a suitable control cabinet. Recommended protection includes dry-running prevention, motor overload protection, phase monitoring and abnormal-voltage protection.
Before ordering, confirm the 200 mm minimum well diameter, required 32 m³/h flow, calculated system head, well depth, operating water level, discharge distance, power supply and cable length. These details determine whether this model matches the actual project.
It can be used in deep wells for agricultural irrigation, clean-water supply, tank filling, groundwater transfer and pressure boosting where the required duty is close to 32 m³/h at 144 m head.
The nine stages increase water pressure progressively. This arrangement enables a narrow borehole pump to produce the head required for deep lifting and pressurized delivery.
Yes, when the sprinkler system requires a flow and pressure compatible with the pump’s performance. Terrain elevation, pipe length and sprinkler operating pressure must be included in the head calculation.
Yes. The pump can transfer clean water from a well to an elevated tank if the total elevation and pipeline losses remain within the pump’s operating range. Tank-level controls can provide automatic operation.
No. The model requires a minimum applicable well diameter of 200 mm. A smaller well requires a pump designed for a smaller casing size.
Standard cast iron is intended for normal clean-water applications. The water composition should be reviewed before use in saline, acidic or chemically aggressive conditions.
The actual flow will decrease as system head increases, and the required duty may fall outside the recommended operating range. A higher-head model should be considered if the calculated system head exceeds this pump’s suitable range.
Use a properly rated control panel with motor-overload, phase, voltage and dry-running protection. Water-level monitoring is particularly important when the well yield is uncertain.
If you are interested in the product, contact 2bvideo.com for more information for more information
The information of 2bvideo.com limited shown above is provided by the user or collected on the network. Video 2B does not guarantee the authenticity,accuracy and legitimacy of 2bvideo.com limited information. Video 2B does not involve legal relationships and disputes between users arising from transactions other than secured transactions on this website. Disputes shall be settled by you through negotiation. If you are the person in charge or relevant employee of this enterprise, if you find that the enterprise information is incorrect or want to manage thiscompany, please contact us jacklee1558@gmail.com, after you claim the enterprise, you can obtain management permission, publish supplyand demand information, bring consulting orders, and remove page advertisements.
Main Product:
Submersible Pump,
Sewage Pump,
Fountain Pump,
Split Case Pump ,
Axial Flow Pump,